Análisis de Falla del Dispositivo de Sujeción de una Fresadora
Different engineering tools were used in this research in order to determine the cause of failure of a milling machine clamp device. The metallographic analysis was done and according to the data the author gave several recommendations to avoid clamp failures in future designs specially in the manuf...
Guardado en:
| Autor principal: | |
|---|---|
| Formato: | Artículo |
| Lenguaje: | español |
| Publicado: |
2001
|
| Materias: | |
| Acceso en línea: | https://dialnet.unirioja.es/servlet/oaiart?codigo=9821390 |
| Etiquetas: |
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
| Sumario: | Different engineering tools were used in this research in order to determine the cause of failure of a milling machine clamp device. The metallographic analysis was done and according to the data the author gave several recommendations to avoid clamp failures in future designs specially in the manufacturing processes, mechanical design and the heat treatment of the grey cast iron of which the clamp was fabricated. |
|---|