Kalman Filter-Based Harmonic Distortion Mitigation Technique for Microgrid Applications

<p id="p1">This work presents a Kalman filter-based harmonic mitigation technique that can be used to reduce the total harmonic distortion (THD) of grid-injected current by reducing the harmonic distortion. Throughout the power supply system, power electronic converters have become increasingly used...

Full description

Saved in:
Bibliographic Details
Main Authors: Iqbal, Hasan, Khalid, Asadullah, Riggs, Hugo, Sarwat, Arif
Format: Book Chapter
Language:English
Published: IntechOpen 2024
Subjects:
Online Access:https://www.intechopen.com/chapters/1179151
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:<p id="p1">This work presents a Kalman filter-based harmonic mitigation technique that can be used to reduce the total harmonic distortion (THD) of grid-injected current by reducing the harmonic distortion. Throughout the power supply system, power electronic converters have become increasingly used in recent years, which has resulted in more reactive power and harmonics. In a power system, harmonics add to noise and lower power quality. A study in MATLAB/Simulink 2022b for improving the THD of renewable energy injected grid currents using seven-level packed u-cells (PUC7) has been undertaken to improve the grid-injected current THD with Kalman filter-based harmonic mitigation technique. With the Kalman filter-based harmonic mitigation techniques, the THD for the grid-injected current is improved from 6.32 to 2.49% when compared to the grid-injected current without the Kalman filter-based technique.</p>
ISBN:978-0-85466-566-2
DOI:10.5772/intechopen.1005285